Technical Reports


The preservative confidentiality of formalin 10% on post-dental implant stability (in vitro study)

,  ,  

1 PhD, Lecturer, Department of OMFS, College of Dentistry, University of Mosul, Nineveh, Iraq

2 BDS, FIBMS (MF), Assistant Professor, Department of OMFS, College of Dentistry, University of Mosul, Nineveh, Iraq

3 BDS, MSc, Lecturer, Department of OMFS, College of Dentistry, University of Mosul, Nineveh, Iraq

Address correspondence to:

Alyaa I Naser

BDS, MSc, Lecturer, Department of OMFS, College of Dentistry, University of Mosul, Nineveh,

Iraq

Message to Corresponding Author


Article ID: 100041D01AA2021

doi: 10.5348/100041D01AA2021TR

Access full text article on other devices

Access PDF of article on other devices

How to cite this article

Aldabagh AHN, Deleme ZH, Naser AI. The preservative confidentiality of formalin 10% on post-dental implant stability (in vitro study). Edorium J Dent 2021;8:100041D01AA2021.

ABSTRACT


Introduction: The dental implant steadiness has been estimated in clinical trials, but a precise amount is frequently tough in experimental simulations. In such circumstances, the amount of implant stability quotient (ISQ) inside the jawbone is desirable afterward formalin fixation.

Aim: This research aims to explore the influence of formalin 10% fixation on the implant stability.

Material and Methods: Twelve dental implants (Dentium Co. Ltd, Suwon, Korea) and four fresh natural tibia bones of sheep gained from the slaughter workshop had been utilized in this research, the implants inserted in the bone specimen then fixed in formalin 10%, and the ISQ was calculated employing device named Osstell mentor at day zero, day 10, day 30, day 60, and day 90.

Result: Implant stability quotient readings were showed no significant differences among evaluated times. Conclusions: These findings propose that bone fixation in formalin does not disturb the implant stability quotient after fixation in bone.

Keywords: Dental implant, Formalin, Preservative

SUPPORTING INFORMATION


Author Contributions

Abdul Hameed N Aldabagh - Substantial contributions to conception and design, Acquisition of data, Analysis of data, Interpretation of data, Drafting the article, Revising it critically for important intellectual content, Final approval of the version to be published

Ziad H Deleme - Substantial contributions to conception and design, Acquisition of data, Analysis of data, Interpretation of data, Drafting the article, Revising it critically for important intellectual content, Final approval of the version to be published

Alyaa I Naser - Substantial contributions to conception and design, Acquisition of data, Analysis of data, Interpretation of data, Drafting the article, Revising it critically for important intellectual content, Final approval of the version to be published

Guaranter of Submission

The corresponding author is the guarantor of submission.

Source of Support

None

Data Availability

All relevant data are within the paper and its Supporting Information files.

Conflict of Interest

Authors declare no conflict of interest.

Copyright

© 2021 Abdul Hameed N Aldabagh et al. This article is distributed under the terms of Creative Commons Attribution License which permits unrestricted use, distribution and reproduction in any medium provided the original author(s) and original publisher are properly credited. Please see the copyright policy on the journal website for more information.