Original Article
| ||||||
Systematizing mandibular reconstruction using the resin frame method | ||||||
Junichi Hayasaka1, Shunji Sarukawa2, Hiroto Itoh3, Yoshiaki Takai4, Mikio Kusama5, Yoshiyuki Mori1, Akitoshi Katsumata6 | ||||||
1Department of Dentistry, Oral and Maxillofacial Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke-shi, Tochigi, Japan
2Department of Plastic Surgery, Jichi Medical University, Yakushiji, Shimotsuke-shi, Tochigi, Japan 3Oral and Maxillofacial Surgery, Nasu Red Cross Hospital, 1081-4 Nakadawara, Otawara-shi, Tochigi, Japan 4Department of Oral and Maxillofacial Surgery, Division of Oral Pathogenesis and Disease Control, Asahi University School of Dentistry, 1851 Hozumi, Mizuho-shi, Gifu 501-0296, Japan 5International University of Health and Welfare Hospital, Oral and Maxillofacial Surgery, 537-3 Iguchi, Nasushiobara-shi, Tochigi, Japan 6Department of Oral Radiology, Division of Oral Pathogenesis and Disease Control, Asahi University School of Dentistry, 1851 Hozumi, Mizuho-shi, Gifu, Japan | ||||||
| ||||||
[HTML Abstract]
[PDF Full Text]
[Print This Article] [Similar article in PubMed] [Similar article in Google Scholar] |
How to cite this article |
Hayasaka J, Sarukawa S, Itoh H, Takai Y, Kusama M, Mori Y, Katsumata A. Systematizing mandibular reconstruction using the resin frame method. Edorium J Dent 2018;5:100029D01JH2018. |
ABSTRACT
| ||||||
Aims: Oral tumors are the most frequent diseases that lead to mandibular defects, but because they are so rare, it is difficult to obtain the necessary large capital investment to establish and introduce a mandibular reconstruction system. Therefore, we developed the Resin Frame method within the current facilities that objectively increases mandibular reproducibility without requiring advanced techniques. Methods: Subjects comprised 25 patients who underwent mandibular reconstruction by the resin frame method in the Department of Dentistry, Oral and Maxillofacial Surgery at Jichi Medical University Hospital between October 2013 and August 2015, and 25 patients who underwent the mandibular reconstruction by the conventional method between September 2007 and November 2011. All mandibles were reconstructed using fibula or iliac bones with a reconstruction plate. The computed tomography (CT) Digital Imaging and Communications in Medicine (DICOM) data before and after the operation were saved. Then, the layer function was used to fuse the pre- and postoperative CT images. Based on measured area, the concordance rate that is matching percentages between pre- and postoperative mandibles were calculated. We evaluated the difference between the concordance rate of the Resin Frame method and the conventional method of mandibular reconstruction. Results: Concordance rates for the resin frame method and conventional surgery were 75.09±6.09% and 67.39±13.44%, respectively, showing a significant difference (p=0.032, p<0.05). Conclusion: The resin frame method represents a mandibular reconstruction system that increases reproduction accuracy and can be implemented at current facilities using simple, objective techniques. Keywords: Concordance rate, Mandibular reconstruction, Resin frame method, Reproducibility | ||||||
INTRODUCTION
| ||||||
Conventionally, mandibular reconstruction lacked objective simulations and depended largely on the subjective judgment of the surgeon [1], [2], [3], [4], [5], [6], [7] . The conventional method used to position the residual mandible uses a metal repositioning plate [8]. This method is excellent for conserving the position of residual mandible that has not been resected, but when the defect (reconstructed portion) is extensive, interference commonly occurs between the repositioning plate and the plate used to fix grafted bone. Furthermore, due to the subjective nature of the procedure, placement of grafted bone relies heavily on the technical expertise and experience of the surgeon, resulting in unstable reproducibility of the reconstructed mandible. Furthermore, repositioning plates are quite expensive [9]. To address these problems, we developed the resin frame method to objectively systematize the mandibular reconstruction procedure and increase its reproducibility without requiring a large-scale capital investment or advanced techniques that need expensive machine parts and software. | ||||||
MATERIALS AND METHODS
| ||||||
Subjects This study was approved by the ethics committee of Jichi Medical University, and written informed consent was obtained from all participants. In cases where obtaining consent was impossible, the opt-out model was used based on the guidelines of confidentiality of personal information.
Resin frame method
Design of the reconstructed mandible
Creation of the resin frame
Creation of a position template for mandibulectomy
Creation of the grafted bone model
Reproduction of separated parts of the mandible
Reconstruction of occlusal units and repositioning of preserved mandibular bone within the resin frame
Confirming reproducibility of preoperative design
Reconstructed plate fixation, resin frame removal, and grafted bone
placement and fixation
Image evaluation method for the reconstructed mandible
| ||||||
RESULTS | ||||||
Little difference was seen between the resin frame method group and conventional method group in terms of age, sex ratio, diagnosis, or mandibular defect range (Table 1). Fibula was frequently used as graft bone in many cases treated using the resin frame method, and many cases used ilium as graft bone in conventional surgery. Regarding the method of graft bone fixation, a reconstruction plate was used in all 25 resin frame cases. In conventional surgery, fixation was achieved using a mini-plate (12 cases), mini-plate and screws (7 cases), or screws alone (6 cases) (Table 2). Concordance rates for the resin frame method and conventional surgery were 75.09±6.09% and 67.39±13.44%, respectively, showing a significant difference (p=0.032, p<0.05 (Table 3). | ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
| ||||||
DISCUSSION | ||||||
Mandibular reconstructions using vascularized osteocutaneous flaps have been reported since 1977, with reconstructions using fibula, ilium, and scapula as the most common [1],[8], [10], [11], [12], [13]. When 3D printing became available, 3D models started to be used for preoperative simulation [14], [15], [16]. The following method was developed: on the 3D model, after mandibular separation, a recording repositioning plate was adjusted by bridging to a metal plate between segments of conserved mandible [16], [17], [18]. Position of the residual mandible was recorded by mounting the device in the visual field prior to segmental mandibulectomy. Later, a method was reported in which the mandible was repositioned after segmental mandibulectomy on the basis of positional information recorded in the resin before the operation [13]. However, these methods emphasized repositioning of the residual mandible, and the main purpose was to recover subjective masticatory ability [19]. There were few reports about evaluation of the differences in accuracy between mandible reconstruction by free hand versus surgical guide template [20]. In October 2013, we developed the resin frame method using the new concept of “reconstructing mandibular shape and occlusion according to a preoperative design using objective procedures”. The resin frame is a device that records the results of mandibular reconstruction performed on a 3D model before the operation by fixing the pre-bent reconstruction plate, using autopolymerizing resin. Using this device, the separated residual mandible is incorporated into the resin frame, allowing easy restoration of continuity [8], while the accurately repositioned and fixed reconstructed plate is used as a guide for positioning the graft bone, enabling objective, highly reproducible, and accurate reconstruction. This finding proved that the concordance rate was significantly higher for the resin frame method than for the conventional method, because the subjectively determined operations by the surgeon using the conventional method were changed to objective operations, eliminating the effects of surgical technique. The resin frame method offers the following characteristics. First, the 3D model was trimmed and the reconstruction plate was pre-bent to align with the form of the bone that was grafted to the mandible. This “trimming” increased the reproducibility of grafted bone positioning during the operation and minimized gaps between the grafted bone and reconstructed plate. In the conventional method, no “trimming” was performed. Such “trimming” is also believed to greatly affect the postoperative form of the mandible. In addition, the template was created for segmental mandibulectomy, according to the preoperative plan, improving the accuracy of reproduction for the separated parts of the mandible. These operations eliminated the adverse effects of fixation of a reconstruction plate and transplanted bone on the design and fixation of the grafted bone. Second, the reconstructed mandible designed preoperatively showed high reproducibility. By positioning and fastening the reconstructed plate according to the preoperative design, the plate could readily be used as a target to place and fix grafted bone. Also, inserting the grafted bone model into separated parts of the mandible to increase reproduction accuracy made it possible to ensure that the mandible was accurately separated and the residual mandible and plate were positioned according to the preoperative design. In addition, the “wing” projection was added to prevent fastening to grafted bone when the reconstruction plate was distorted and to prevent resin frame rotation or distortion, which increased reproducibility when the resin frame was mounted. The absence of any cases of dislocation or forward rotation of the articular process, which occurred after operations using the conventional method, and the significantly higher concordance rate with the resin frame method verified the efficacy of the wing. Third, occlusion was restored. When continuity of the mandible is broken via segmental mandibulectomy and a splint alone is used to fasten the bone, rotation occurs as a result of over-tightening of the intermaxillary fixing wire, causing postoperative occlusion that differs from preoperative occlusion. With the resin frame method, if the jaw is not edentulous, a bite plate can be created before the procedure and used in combination with intermaxillary fixing screws perioperatively to reproduce occlusion. In medical fields, 3D imaging and printing applications have received much attention [4],[15],[21], but most presuppose the use of a large-scale operation simulation/navigation system or CAD/CAM system [5], [5], [6], [7], [22]. In recent years, simulations have been used to create many systems for recipient and donor sites, and even to pre-bend fixation devices [5], [6], [7], [22]. However, those applications are not generally used because they involve many operation steps, causing most of the time to be spent on capital investment and learning the systems. In contrast, the resin frame method has the advantage of easy introduction to current facilities without the need for new equipment. This is because inexpensive gypsum 3D models can be created by outsourcing and then modified by the surgeons themselves, for use in assisting with surgical procedures. Currently, while highly accurate resection of the graft bone can be performed using surgical guides, reconstruction plate bending or fixation maneuvers are still greatly influenced by the skills of the surgeon [23]. In the resin frame method, preoperative design of the donor site does not have to be excessively strict. This is because the model provides flexibility for adjusting anastomotic vessels and bone graft fragments as well as perioperative occlusal reconstruction. Fixation of the grafted bone is objective and does not affect the form of the reconstructed mandible, since a reconstruction plate fixed according to the preoperative design is placed as a guide. In addition, the accuracy of a 3D model of the jaw is affected by various elements, from CT imaging devices and data-editing software to molding devices, so errors can also occur in virtual simulation. Conserved occlusion is restored by reconstruction of the occlusal unit first (similar to occlusal restoration in mandibular fractures), followed by restoration of the detached mandibular bone to restore the mandibular morphology. | ||||||
CONCLUSION
| ||||||
The resin frame method is a hybrid of the conventional method and a virtual simulation system. By systematizing mandibular reconstruction procedures and increasing objectivity, this method successfully improves mandibular reconstruction accuracy from an aesthetic and functional standpoint. | ||||||
REFERENCES
| ||||||
|
[HTML Abstract]
[PDF Full Text]
|
Acknowledgements
The present study was partially funded by a MEXT/JSPS KAKENHI Grant (grant number JP17K11683) from Japan. |
Author Contributions
Junichi Hayasaka – Substantial contributions to conception and design, Acquisition of data, Analysis and interpretation of data, Drafting the article, Revising it critically for important intellectual content, Final approval of the version to be published Shunji Sarukawa – Analysis and interpretation of data, Revising it critically for important intellectual content, Final approval of the version to be published Hiroto Itoh – Analysis and interpretation of data, Revising it critically for important intellectual content, Final approval of the version to be published Yoshiaki Takai – Analysis and interpretation of data, Revising it critically for important intellectual content, Final approval of the version to be published Mikio Kusama – Analysis and interpretation of data, Revising it critically for important intellectual content, Final approval of the version to be published Yoshiyuki Mori – Analysis and interpretation of data, Revising it critically for important intellectual content, Final approval of the version to be published Akitoshi Katsumata – Analysis and interpretation of data, Revising it critically for important intellectual content, Final approval of the version to be published |
Guarantor of Submission
The corresponding author is the guarantor of submission. |
Source of Support
None |
Consent Statement
Written informed consent was obtained from the patient for publication of this study. |
Conflict of Interest
Author declares no conflict of interest. |
Copyright
© 2018 Junichi Hayasaka et al. This article is distributed under the terms of Creative Commons Attribution License which permits unrestricted use, distribution and reproduction in any medium provided the original author(s) and original publisher are properly credited. Please see the copyright policy on the journal website for more information. |
|